Skip to main content
Abstract Articles

Association of Race and Ethnicity with Triage Pulse Oximetry Measurements in a National Emergency Department Cohort

Authors: Alexander Sonaglia ( Wayne State University School of Medicine) , Timothy Chalom ( Wayne State University School of Medicine) , Ka Ming ( Gordon Ngai Wayne State University School of Medicine) , Jeffrey Kline ( Wayne State University School of Medicine)

  • Association of Race and Ethnicity with Triage Pulse Oximetry Measurements in a National Emergency Department Cohort

    Abstract Articles

    Association of Race and Ethnicity with Triage Pulse Oximetry Measurements in a National Emergency Department Cohort

    Authors: , , ,

Download

Downloads:
Download HTML

02b853c6-76f6-48c2-b0fc-982fd118137d

Introduction

Pulse oximetry is a ubiquitous, non-invasive tool for assessing arterial oxygen saturation (SpO₂) in clinical care.1 However, evidence suggests that its accuracy is compromised in individuals with darker skin pigmentation—particularly during hypoxemia—due to melanin’s absorption of infrared light2 and historical calibration biases.3 Using a large, multicenter U.S. emergency department (ED) database, we aimed to assess the association between patient race/ethnicity and triage SpO₂ readings in a real-world setting.

Methods

We conducted a retrospective cohort study using the CDC’s RESP-LENS dataset (Dec 2021–2024), including adult patients (≥18 years) with an acute respiratory illness. The primary outcome was the ordinal triage SpO₂ category (Normal ≥95%, Low 91-94%, Very Low ≤90%). The association between self-reported race/ethnicity and SpO₂ category was analyzed using a multivariable ordinal logistic mixed-effects model, with hospital as a random effect and adjusting for age, sex, smoking status, comorbidities, altitude, and COVID-19 wave.

Results

The analysis included 873,276 adult ED visits. After full adjustment, Black patients had significantly higher odds of being classified in a higher SpO₂ category compared with White patients (Odds Ratio [OR], 1.59; 95% CI, 1.56–1.61). Similar, statistically significant associations were observed for Asian (OR, 1.31; 95% CI, 1.25–1.36), Hispanic (OR, 1.46; 95% CI, 1.43–1.49), and Other race/ethnicity individuals (OR, 1.30; 95% CI, 1.28–1.33).

Conclusion

In a large national cohort, we observed significant differences in triage pulse oximetry readings between racial and ethnic groups, consistent with small prior studies that suggested overestimation of oxygen saturation in non-White patients. These findings underscore the need to consider race in clinical guidelines that incorporate pulse oximetry to advance equity in respiratory care.

Tables and Figures

updated graph.jpg

Figure 1: Odds ratio for higher SpO2 category plotted for each predictor category

References

1. Tekin K, Karadogan M, Gunaydin S, Kismet K. Everything About Pulse Oximetry-Part 2: Clinical Applications, Portable/Wearable Pulse Oximeters, Remote Patient Monitoring, and Recent Advances. J Intensive Care Med. 2023;38(10):887-896. doi:10.1177/08850666231189175

2. Shi C, Goodall M, Dumville J, et al. The accuracy of pulse oximetry in measuring oxygen saturation by levels of skin pigmentation: a systematic review and meta-analysis. BMC Med. 2022;20(1):267. Published 2022 Aug 16. doi:10.1186/s12916-022-02452-8

3. Jamali H, Castillo LT, Morgan CC, et al. Racial Disparity in Oxygen Saturation Measurements by Pulse Oximetry: Evidence and Implications. Ann Am Thorac Soc. 2022;19(12):1951-1964. doi:10.1513/AnnalsATS.202203-270CME

4. Bickler PE, Feiner JR, Severinghaus JW. Effects of skin pigmentation on pulse oximeter accuracy at low saturation. Anesthesiology. 2005;102(4):715-719. doi:10.1097/00000542-200504000-00004

5. Feiner JR, Severinghaus JW, Bickler PE. Dark skin decreases the accuracy of pulse oximeters at low oxygen saturation: the effects of oximeter probe type and gender. Anesth Analg. 2007;105(6 Suppl):S18-S23. doi:10.1213/01.ane.0000285988.35174.d9

6. Sjoding MW, Dickson RP, Iwashyna TJ, Gay SE, Valley TS. Racial bias in pulse oximetry measurement. N Engl J Med. 2020;383(25):2477-2478. doi:10.1056/NEJMc2029240

7. Saft HL, Bhakta NR, Wong AKI, et al. The Affordable Care Act’s call for nondiscrimination: addressing the role of pulse oximetry in racial disparities. Ann Am Thorac Soc. 2025;22(3):313–316. doi:10.1513/AnnalsATS.202408-902PS

76 Views

35 Downloads

Published on
19 Jun 2026
Peer Reviewed

Publication details

  • Article Number: 53

Jump to

File Checksums (MD5)

  • HTML: f91119165a4a5e651da8536e82b26ce4